- A -
Apple CoreStorage/FileVault/Fusion Drive Volumes
- B -
Bad Sectors settings
Binary (byte to byte copy)
BitLocker System Drive Encryption
Broken File Name
Rename and change all invalid symbols to:
Broken File Name options
Button
Buttons
Create virtual volume sets or RAIDs
- C -
Connect to R-Studio settings
Contact information and technical support
Find Previous Versions of the File
Find Template Signature Previous
Remove All Scanned Information
Contextt menu
Create menu
Creating and saving your own RAID configuration
Creating Startup Disks for Mac and Linux Computers
- D -
Data Copy in Text/hexadecimal editor
Data Recovery on HFS/HFS+ File System
Description Files for Various RAID Configurations
Devices to Store Recovered Files
Dialog box
Dialog boxes
Edit Block RAID Layout Presets
Please configure R-Studio Agent for Mac
Please configure R-Studio Agent for Windows
R-Studio Agent for Linux Configuration
There is not enough space on the disk
Drive menu
- E -
Edit menu
Find Template Signature Previous
Editor tabs
Exclusive Region options
- F -
Fast Search for Lost Partitions
File Already Exists
File Information (R-Studio Technician/T80+)
File mask options
File menu
File Systems settings
Default encoding for Ext2/Ext3/Ext4/UFS volumes
Default encoding for HFS volumes
File Type Signature Specification
File Types
Find options
Find/Mark options
Find/mark objects only in real paths, ignore links to folders
Finding Previous File Versions
Forensic Data Collection Audit Log
- H -
Hidden Attribute
- I -
Image options
Image type:
Byte to byte image to a physical disk
Compressed image (R-Drive Image compatible)
VMDK (VmWare Virtual Machine Disk)
- K -
Known File Types settings
- L -
Log settings
Maximum messages in the Event Log
- M -
Main settings
Reset all hidden notifications
Messages
Double-click a logical disk...
- N -
Nested and Non-Standard RAID Levels
- O -
Opening several disks/partitions in one tab
- P -
Panels
Panes
Properties tab
- Q -
- R -
Recover options
Condense successful restoration events:
Open local folder (folders) when done
Recover alternative data streams:
Recover real folders structure
Region options
Contact information and technical support
Installing R-Studio Agent Emergency Startup Media Creator
Starting a Computer with the R-Studio Agent Emergency Startup Disk
R-Studio Agent for Mac main panel
R-Studio Agent for Windows main panel
Contact Informaiton and Technical Support
Installing R-Studio Emergency Startup Media Creator
Properties and Text/Hexadecimal Viewer
Starting a Computer with the R-Studio Emergency Startup Disks
R-Studio Emergency Startup Media Creator
- S -
Scan options
Search options
Settings
Shortcut menu
Smart drive copy
Copy all partitions onto original places
Expand/Shrink partition to whole disk
Smart partition copy
Startup Media Troubleshooting Options
Symbolic Links
Automatic recovery without symlink object path conversion
Don't show symbolic links by default (Technician version)
Recovery as it is (Technician version)
Show folder symbolic links as links to their targets, without target content (Technician version)
Show symbolic links as links to their targets, without target content
Symbolic links display settings
Symbolic links recovery options
Syntaxis of a Description File for RAID Configurations
- T -
Tabs
Technical Information and Troubleshooting
Tools menu
- U -
- V -
Various Disk and Volume Managers
View menu
Volume Sets, Stripe Sets, and Mirrors
- W -
Window
Working with RAID 6 Presets
YOU MUST BE ABSOLUTELY SURE OF WHAT AND WHERE YOU ARE WRITING!
Or you may completely lose all your data.
Before you can physically write anything on a disk, you need to enable writing.
To enable writing,
1 | On the R‑Studio for Linux main panel, select the Tools menu, then Settings , and select Enable Write on the Settings dialog box. |
> | The Editable: status will change to Yes from Read Only . |
Now the object can be edited.
To view/edit an object,
1 | Right-click the object and select View/Edit on the context menu , or |
Select the object and select View/Edit on the File menu
Click the panel regions to learn their functions. |
Panel view options
You may set which panels and bars to enable/disable.
ANSI data |
Select/clear ANSI on the View menu |
OEM data |
Select/clear OEMr on the View menu |
UNICODE data |
Select/clear UNICODE on the View menu |
UNICODE+ data |
Select/clear UNICODE+ on the View menu |
Toolbar |
Select/clear Toolbar on the View menu |
Properties View |
Select/clear Properties View on the View menu |
Sectors View |
Select/clear Sectors View on the View menu |
Data Interpreter View |
Select/clear Data Interpreter View on the View menu |
Template View |
Select/clear Template View on the View menu |
Bookmarks View |
Select/clear Bookmarks View on the View menu |
Find Results View |
Select/clear Find Results View on the View menu |
2 | View the information and make necessary changes |
Select Save Changes on the Tools menu if you want to save changes.
• Select Save Changes on the File menu or • Press the Ctrl+S keys |
There are up to four tabs showing the data in different representations. Actual number of tabs depends on the object and property being viewed/edited.
Std |
Exact attribute data. If the attribute is compressed, R‑Studio for Linux decompresses it prior to showing. |
Unlimited |
Exact attribute data + free space of last cluster. If the attribute is compressed, R‑Studio for Linux decompresses it prior to showing. |
Direct |
Actual data written on the disk. If the attribute is not compressed, it coincides with the Std representation. |
Allocation |
Resident part of the attribute. |
You may view data in 4 various code pages: ANSI/OEM/UNICODE/UNICODE+ by switching on/off the respective code pages in the Code pages buttons or select the appropriate code pages on the View menu.
You may select a pattern according to which the data will be parsed and shown in the parsed data pane. The Data Interpreter shows the data selected on the Template pane in various representations.
You may find the next or previous data that matches the pattern signature on the disk. Right-click the right pane of the editor and select either Find Template Signature Next or Find Template Signature Previous on the context menu. You may also select these items on the Edit menu.
You may also create your own patterns to parse data from various objects.
Text/hexadecimal Editor gives you various ways to navigate into an object. See the Navigating through an Object for more details
Text/hexadecimal Editor gives you various ways to copy selected data navigate in an object. See the Data Copy for more details.
To fill an area with a pattern, select Fill on the Edit menu, and specify the pattern and area on the Fill dialog box.
Fill pattern |
|
HEX |
Field for the pattern to fill the area in the hexadecimal representation |
ANSI |
Field for the pattern to fill the area in the ANSI encoding |
OEM |
Field for the pattern to fill the area in the OEM encoding |
UNICODE |
Field for the pattern to fill the area in the UNICODE encoding |
Fill range |
|
From (hex) |
Field for the start position of the area to fill with the pattern |
To (hex) |
Field for the end position of the area to fill with the pattern |
3 | Click the Save Changes button to save the changes |
• Select Save Changes on the Edit menu or • Press the F2 key |
> | Viewer/Editor will save the changes on the object |
YOU MUST BE ABSOLUTELY SURE OF WHAT AND WHERE YOU ARE WRITING!
Or you may completely lose all your data.
Selecting and saving an area in the Viewer/Editor
You may select an area in the Viewer/Editor panel and save it as a file.
To select and save an area in the Viewer/Editor panel ,
1 | Right-click the beginning of the selection and select Select From on the context menu |
2 | Right-click the end of the selection and select Select To on the context menu |
• Select Select... on the Tools menu and specify an area to select on the Select dialog box, or • Click the start point of the area and drag the mouse cursor to its end. |
If you need to select an entire object, select Select All on the Tools menu or click the Ctrl+A key
3 | Select an appropriate item in the Tools menu to save the data in a required format and specify its file name |
Select:
Save to Binary File... |
to save the data in the binary format (default extension is .bin ) |
Save to Hexadecimal File |
to save the data in the binary format (default extension is .hex ) |
on the Tools menu.
If you select an existing file, R‑Studio for Linux will ask you if you want to append or overwrite the file.
If a remote computer is connected for Data Recovery over Network , the Save as... dialog box will appear when you select a place to save the data. You may save it to the local or remote computer.
> | Viewer/Editor will save the data in the file |
Loading data from an external file
You may load a data from a file and overwrite an area of the object opened in the Viewer/Editor panel.
To load binary data from a file and overwrite an area of the object opened in the Viewer/Editor panel ,
1 | Select an area to overwrite and select Load from File... on the Tools menu |
If a remote computer is connected for Data Recovery over Network , the Open as Binary File dialog box will appear when you select a place to open the data file from. You may open it from the local or remote computer.
2 | Select the necessary file and load the data. |
> | The area in the Viewer/Editor will be overwritten with the new data. |